Catalogue
Mouse anti Human CD4, conjugated with Biotin
Catalog number: 0043Clone | 7E14 |
Isotype | IgG1 |
Product Type |
Single-Color Reagent |
Units | 100 Tests |
Host | Mouse |
Species Reactivity |
Human |
Application |
Flow Cytometry |
Background
Identification of human helper/inducer T cells expressing the 60,000 M.W. surface antigen (HLA class II reactive). CD4 is present in low density on monocytes.
Synonyms: T-cell surface glycoprotein CD4; T-cell surface antigen T4/Leu-3
Source
Immunogen: Derived from the hybridization of mouse NS-1 myeloma cells with spleen cells from BALB/c mice immunized with human perherial blood T lymphocytes.
Product
Product Form: Biotin
Formulation: Provided as solution in phosphate buffered saline with 0.08% sodium azide and 0.2% carrier protein
Purification Method: Protein A/G Chromatography
Concentration: Titered for flow cytometry
Applications
PBMC: Add10 µl of MAB/106 PBMC in 100 µl PBS. Mix gently and incubate for 15 minutes at 2 to 8°C. Wash twice with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze. WHOLE BLOOD: Add10 µl of MAB/100 µl of whole blood. Mix gently and incubate for 15 minutes at room temperature 20°C. Lyse the whole blood. Wash once with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze. See instrument manufacturer’s instructions for Lysed Whole Blood and Immunofluorescence analysis with a flow cytometer or microscope. ALLOPHYCOCYANIN : (APC) conjugates are analyzed in multi-color flow cytometry with instruments equipped with a second laser and proper filters. Laser excitation is at 633 nm with a Helium Neon (HeNe) laser or a 600-640 nm (633 nm) range for a Dye laser. Peak fluorescence emission is at 660 nm. RPE-Cy-5 +: Use 5 µl of solution, rather than 10 µl as above. Excites at 488nm and emits at 670nm. Store protected from light.
Functional Analysis: Flow Cytometry Staining
Storage
Product should be stored at 4-8°C. DO NOT FREEZE
Product Stability: See expiration date on vial
Shipping Conditions: Room Temperature
Caution
This product is intended FOR RESEARCH USE ONLY, and FOR TESTS IN VITRO, not for use in diagnostic or therapeutic procedures involving humans or animals. It may contain hazardous ingredients. Please refer to the Safety Data Sheets (SDS) for additional information and proper handling procedures. Dispose product remainders according to local regulations.This datasheet is as accurate as reasonably achievable, but Nordic-MUbio accepts no liability for any inaccuracies or omissions in this information.
References
1. Thymus Dependent Membrane Antigens in Man: Inhibition of Cell-Mediated Lympholysis by Monoclonal Antibodies to the TH-2 Antigen. Evans,R.L., Wall,D.W., Platsoucas,C.D., Siegal,F.P., Fikrig,S.M., Testa,C.M, and Good,R.A. Proc. Nat. Acad. Sci. 78,544,1981.
2. Novel Immunoregulatory Functions of Phenotypically Distinct Subpopulations of CD4+ cells in the Human Neonate. Clement,L.T., Vink,P.E., Bradley,G.E. J. Immunology 145(1):102-8,1990 .
3. Antigen Presentation by the CD4 Positive Monocyte Subset. Szabo,G., Miller,C.L., Kodys,K., J. Leukoc. Biol. 47(2): 111-20,1990.
4. Human Immunodeficiency Virus Infection is Efficiently Mediated by a Glycolipid-Anchored form of CD4. Diamond,D.C., Finberg,R., Chaudhuri,S., Sleckman,B.P., Burakoff,S.J., Proc. Natl. Acad. Sci. 87(13):5001-5,1990.
5. Development Regulation of the Intrathymic T cell Precursor Population. Adkins,B., J. Immunol. 146(5):1387-93,1991.
6. Induction of CD4 and Susceptibility to HIV-1 Infection in Human CD8+ T Lymphocytes by Human Herpesvirus 6. Lusso,P., De Maria,A., Malnati,M., Lori,F., DeRocco,S.E., Baseler,M., Gallo,R.C., Nat. 349(6309):533-5,1991.
7. Immunofluorescence Measurement in a Flow Cytometer using Low-Power Helium Neon Laser Excitation. Shapiro, H.M, Glazer, A.N., Christenson, L., Williams, J.M., and Strom, T. B. Cytometry 4,276, 1983.
8. Comparison of Helium Neon and Dye lasers for Excitation of Allophycocyanin. Loken, M.R., Kiej, J.F. and Kelly, K.,A. Cytometry 8, 96, 1987.
Cy-5 + Portions of this product is manufactured under license from Carnegie Mellon University, U.S. Patent Number 5,268,486.
Product Specific References:
1. Gardner, J.P. et al. 'Robust, but transient expression of adeno-associated virus-transduced genes during human t lymphopoisis.' Blood, 1997, 90, 4854-4864.
Protein Reference(s)
Database Name: UniProt
Accession Number: P01730 (Human)
Species Accession: Human
Safety Datasheet(s) for this product:
NM_Sodium Azide |